Operating Instructions | KBL 4800 alpha
48
10.14 Ventilation and
air-conditioning
In order to preserve the performance of the air-
conditioning unit, clean the heat exchangers after
500 - 600 hours of operation.
Airconditioning
unit
Heat exchanger
Condensate pump
Condensate tray
Open the bed part.
Clean the heat exchanger.
Vacuum it carefully, paying attention not to
damage the fins.
SERVICING THE VENTILATION SYSTEM
Check all hose connections.
Remove any kinks in the air hoses. Replace
defective hoses immediately.
The exhaust air hose must not exceed a
maximum length of 6 m if there is no auxiliary
fan installed.
CHECKING THE CONDENSATE PUMP
The condensate pump pumps away the
condensation water at timer-controlled intervals.
Check the function of this pump with each tube
replacement.
Fill some water into the condensate tray .
Use a hose and a funnel to do so.
Make sure that the water does not spill over.
Start a tanning session and then wait for 20
minutes.
The filling level of the tray must then be below
the pump level.