10.2 Maintenance intervals
MAINTENANCE PLAN
Component
500 h / 6 months
1500 h / 1 Year
2000 h / 1 Year
10000 h / 4 Years
10000 h / 10 Years
Activity
Acrylic pane
(bed)
X
Inspect and replace
as necessary
X
Replace
Acrylic panes
(others)
X
Inspect and replace
as necessary
X
Replace
Springs of the
canopy drive
X
Inspect and replace
as necessary
X
Replace
Chassis and
associated
fasteners
X
Inspect and replace
as necessary
X
Replace
Wiring and
associated
plugs / terminal
connections
X
Inspect and replace
as necessary
X
Replace
Contactors
X
Inspect and replace
as necessary
X
Replace
UV-Filter
Facial tanners
X
Inspect and replace
as necessary
X
Replace
Component
After approx. 200
operating hours
After approx. 800
operating hours
After approx. 1000
operating hours
After approx. 1100
operating hours
Activity
Tubes
CPI
X
Replace
Tubes
Electronic power
X
Replace
aquaCool
nozzles
X
Inspect and replace
as necessary
X
Replace
Component
After approx. 500
operating hours
After approx. 3000
operating hours
Activity
Facial
tanners
X
Replace
Air hoses
X
Inspect and replace as
necessary
Air-conditioning
unit
X
Clean the heat exchangers and
check the condensate pump.
Additional or recurring inspections
Every 6 months
cleaning service
Make sure that the inside and outside of the
tanning device is cleaned and free from dust,
fluff or objects.
See 9.1 -> Additional cleaning activities.
Every 12 months
inspection
Please note that the tanning device must be
inspected regularly by a KBL authorized rep-
resentative every 12 months (from date of
installation) to maintain its proper condition!.
10 Years
inspection
If the tanning device is in use for longer than
10 years / 10000h, it must be completely
overhauled by qualified, trained and autho-
rized service technicians.
On start up
If the tanning device has not been used for
a longer period of time, then it must first be
inspected by qualified, trained and authorized
service technicians before being put back into
operation.
Protective
pane-switch
- Filter panes
Test the switches with each removing
of filter panes

Table of Contents