4.4.4 Switch contact output [X2]
The switch contact output is a potential-free relay contact and can be used for activating a
fan in the garage. This can be necessary with some vehicles. Please consider car require-
ments, building requirements and Electric code for installation requirements. The output is
not fail-safe! If a fan is used, the corresponding DIP-switch settings must be selected.
Circuit diagram:
Electrical requirements:
- Safety extra-low-voltage Vcc < 50V
AC
- F 0.5A current limiting device
Connection:
Connect the wires to the switch contact output (please refer to the "Terminals [X1/X2]"
chapter for details about the terminal).
DIP-switch setting
DIP-switch setting
The use of the switch contact (e.g. for the fan
specification) must be activated by a DIP-switch
setting.
Using the switch contact output:
- "Yes": DSW1.2 = ON
- "No": DSW1.2 = OFF (Default)