Model 2231A Triple-channel DC Power Supply Reference Manual Section 5: SCPI command reference
077100401/September 2014 5-15
Arguments 0|1
Returns 0|1
Examples Outp:enab 1
OUTPut:TIMer[:STATe]
This command is to set the output timer state for the presently selected channel.
Item Description
Group Output
Syntax OUTPut:TIMer[:STATe] <bool> <Arguments>
OUTPut:TIMer:STATe?
Arguments 0|1|ON|OFF
Returns 0|1
Examples Outp:tim 1
OUTPut:TIMer:DELay
This command is to set the delay time for the output timer function.
Item Description
Group Output
Syntax OUTPut:TIMer:DELay <Arguments>
OUTPut:TIMer:DELay?
Arguments 0.1-99999.9
Unit s (seconds)
Returns The timer delay
Examples Outp:tim:del 5
Outp:tim:del?
OUTPut:TRACk[:STATe]
This command is to set the tracking status of CH1 and CH2.
Item Description
Group Output
Syntax OUTPut:TRACk[:STATe] <bool>
[SOURce:]OUTPut:TRACk[:STATe]?
Arguments 0|1|ON|OFF
Returns 0|1
Item Description