Series 3700A System Switch/Multimeter Reference Manual Section 11: TSP command reference
3700AS-901-01 Rev. D/June 2018 11-57
Example
channel.setpole("slot5", 4)
channel.setbackplane("slot5", "5911, 5922")
print(channel.getbackplane("slot5"))
Assume a Model 3720 in slot 5.
Set all channels on the card in slot 5 to be 4-
pole, which makes the card have 30 4-pole
channels.
Set all channels in slot 5 to have associated
analog backplane relays 911 and 922 on slot
5.
Get the associated analog backplane relays
for channels on slot 5.
Output:
5911,5922,5911,5922,5911,5922,591
1,5922,5911,5922,5911,5922,591
1,5922,5911,5922,5911,5922,591
1,5922,5911,5922,5911,5922,591
1,5922,5911,5922,5911,5922,591
1,5922,5911,5922,5911,5922,591
1,5922,5911,5922,5911,5922,591
1,5922,5911,5922,5911,5922,591
1,5922,5911,5922,5911,5922,591
1,5922,5911,5922
Also see
Data retrieval commands (on page 9-3)
channel.close() (on page 11-46)
channel.exclusiveclose() (on page 11-52)
channel.open() (on page 11-76)
channel.pattern.getimage() (on page 11-78)
channel.pattern.setimage() (on page 11-79)
channel.pattern.snapshot() (on page 11-82)
channel.setbackplane() (on page 11-87)
channel.setpole() (on page 11-96)
dmm.close() (on page 11-160)
dmm.open() (on page 11-211)
scan.background() (on page 11-313)
scan.execute() (on page 11-317)

Table of Contents

Other manuals for Keithley 3720-ST

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 3720-ST and is the answer not in the manual?

Keithley 3720-ST Specifications

General IconGeneral
BrandKeithley
Model3720-ST
CategoryMultimeter
LanguageEnglish

Related product manuals