Model 2701 Ethernet-Based DMM / Data Acquisition System
User’s Manual
A GREATER MEASURE OF CONFIDENCE

Table of Contents

Other manuals for Keithley 2701

Questions and Answers

  • M
    Matthew MurphyJul 26, 2025
    How to fix Keithley Measuring Instruments Model 2701 when the web page opens but settings are blank?
    • R
      Robert BakerJul 27, 2025
      If the web page opens but settings and data fields are blank, check the subnet mask on both the Model 2701 and the PC to ensure they match. Add the IP address of the Model 2701 to trusted sites in IE and allow ActiveX controls. Ensure only one connection to the 2701 exists at a time. Cycle power to the 2701 to close past connections. Use the correct cable type (straight through for direct connection without a hub, not crossover). Ensure each node has a unique IP address but shares the same subnet mask and network ID. Check the interface card setup. Verify the IP address and refresh if needed. On the 2701 front panel, press Shift >> RS-232 and set to OFF if it is set to use Serial Interface.
  • A
    andrew48Nov 9, 2025
    What to do if I'm not able to open the Keithley Measuring Instruments Model 2701 web page?
    • M
      Mr. Paul WalshNov 9, 2025
      If you cannot open the Model 2701 web page, first, verify the cable connection by checking if the Link/Act or 100bt LED near the Ethernet connector is on or blinking. If network software issues arise, try selecting the standard VGA driver in Windows Setup. If this resolves the problem, attempt to obtain the latest driver versions. Also, IP addresses assigned by the IS/IT department may require some time to become active, so check with them regarding when the IP address will be active. Ensure you inform the IS/IT department where you intend to connect the 2701 to the network, as the location may determine the correct subnet. If connected to a router or switch, the MAC address is usually cached with the IP address for some time; contact your IS/IT department for details on the router/switch ...

Keithley 2701 Specifications

General IconGeneral
Max Voltage300 V
Max Current3 A
Frequency Range3 Hz to 500 kHz
Frequency Accuracy0.01%
Weight3.6 kg
Measurement FunctionsFrequency, Temperature
InterfaceIEEE-488 (GPIB), RS-232
DC Voltage Range300 V
DC Current Range3 A
AC Voltage Range300V
AC Current Range1 μA to 3 A
Resistance Accuracy0.01%
Channels10
Dimensions213mm x 88mm x 370mm