Resolution | 8.5 digits |
---|---|
DC Voltage Accuracy | ±0.0006% |
Maximum DC Voltage | 1000 V |
Maximum AC Voltage | 750 V |
Maximum DC Current | 3 A |
Maximum AC Current | 3 A |
Connectivity | GPIB, RS-232 |
DC Voltage Range | 100 mV to 1000 V |
AC Voltage Range | 100 mV to 750 V |
Resistance Range | 10 Ω to 1 GΩ |
Model | 2002 |
Category | Multimeter |
Interface | GPIB, RS-232 |
AC Current Accuracy | ±0.1% |
Frequency Range | 0.1Hz to 300kHz |
Display | VFD |
Type | Digital |
Power Supply | 100-240V AC, 50/60Hz |
Current Range (DC) | 100 μA to 3 A |
Current Accuracy (DC) | ±0.01% |
Current Range (AC) | 100 μA to 3 A |
Current Accuracy (AC) | ±0.1% |
DC Current Range | 100 μA to 3 A |
AC Current Range | 100 μA to 3 A |
Provides an overview of the Model 2002 multimeter and its manual structure.
Highlights key capabilities of the Model 2002, including measurement functions and display.
Details warranty service procedures and contact information.
Explains how changes to the manual will be communicated.
Defines safety symbols and terms used in the manual and on the instrument.
Refers to Appendix A for detailed product specifications.
Instructions for inspecting the instrument after unpacking.
Lists available options and accessories for the Model 2002.
Outlines the sections covered in the front panel operation chapter.
Information on connecting to line power, warm-up, and power-up sequence.
Covers display formats, messages, and multiple display features.
Describes the measurement functions of the instrument (DCV, ACV, DCI, ACI, Ohms, Freq, Temp).
Explains how range selection affects resolution, accuracy, and maximum signal.
Details on using the relative feature to null offsets or subtract baseline values.
Discusses front panel triggering, configuration, and external triggering.
Covers buffer use, data storage, and recalling data, time stamp, and statistics.
Explains the use of digital filter types to reduce reading noise.
Describes calculations that can be performed on readings in continuous operation.
Discusses setting up internal and external scans, ratio, and delta calculations.
Covers selections controlled from the main menu, including setup, GPIB, calibration, and tests.
Provides reference information on programming the Model 2002 over the IEEE-488 bus.
Explains instrument connections to the IEEE-488 bus.
Explains how to set the primary address from the front panel.
Summarizes programming using QuickBASIC 4.5 with the IEEE interface.
Covers general IEEE-488 commands for basic operations like placing the unit in remote.
Covers status indicators, messages, and LOCAL key use for IEEE-488 operation.
Explains the various registers and queues that make up the status structure.
Explains the operation process (Trigger Model) over the IEEE-488 bus.
Covers the syntax rules for common commands and SCPI commands.
Covers the IEEE-488.2 common commands used by the Model 2002.
Covers the signal oriented commands used by the Model 2002.
Covers math operations: CALCulate1 (math), CALCulate2 (buffer), CALCulate3 (limits).
Controls the display of readings and messages on the Model 2002.
Selects the data format for transferring instrument readings over the bus.
Controls the Model 1801 Nanovolt Preamp.
Sets the polarity for the digital output port.
Configures and controls switching.
Configures measurement functions (Sense 1) and reads digital input (Sense 2).
Sets the logic level (true or false) of each digital output line.
Controls the status registers.
Contains miscellaneous commands not covered by other subsystems.
Configures and controls data storage into the buffer.
Configures the three layers of the Trigger Model.
Configures and controls measurement units for TEMP and ACV.
Provides DCV input characteristics and accuracy specifications.
Specifications for ACV measurements, including RMS, average, peak, and crest factor.
Specifications for ACI and DCI measurements.
Specifications for resistance measurements.
Specifications for the DC in-circuit current measurement function.
Provides information on using the Model 2002 HP3458A emulation mode for compatibility.
Details how to display the firmware revision level.
Step-by-step guide to enable HP3458A emulation mode via the GPIB menu.
Lists commands not supported by the Model 2002 HP3458A emulation mode.
Discusses command syntax and compatibility issues for HP3458A emulation.
Explains default parameters assumed when omitted, and unsupported syntax.
Describes the use of spaces or commas for parameter separation.
Lists short forms for common FUNC commands.
Describes behavior for unsupported query commands.
Details commands for emulation mode error checking.
Summarizes supported commands with descriptions.
Programs the A/D integration time.
Enables or disables the autorange mode.
Enables or disables the autozero mode.
Requests the calibration date.
Clears status register bits.
Programs the time interval between trigger and sample events.
Enables/disables display, clears display, sends message to display.
Enables certain error conditions to set the error bit in the status register.
Requests the error register value.
Requests the error number and error response string.
Selects the frequency measurement function.
Selects the signal type for frequency or period measurements.
Selects the measurement function and range.
Requests the instrument's identification string.
Requests the AC power line frequency.
Requests the number of readings presently stored in memory.
Enables/disables reading memory and designates storage mode.
Clears reading memory and designates storage format for new readings.
Requests reading memory size.
Programs the number of display digits used for readings.
Programs the A/D converter integration time in power line cycles.
Programs the number of readings per trigger and the trigger event.
Enables or disables the offset-compensated ohms mode.
Programs the data format for both normal and memory readings.
Requests a report of installed options.
Selects the period measurement function.
Selects one of two preset instrument configurations.
Selects the measurement range.
Resets the Model 2002 to the power-on state.
Requests the main and front panel revision levels.
Requests readings stored in memory.
Enables or disables status register bits that can cause an SRQ.
Recalls an instrument configuration from memory.
Selects the RMS conversion technique for AC and AC+DC measurements.
Enables SRQ.
Stores the instrument's present configuration in memory.
Requests the status register value.
Programs the interval between readings and number of samples per trigger.
Programs the trigger event.
Specifies the event that arms the trigger event.
Requests the internal temperature of the Model 2002.
Requests INPUTS switch status.
Defines the timer sample interval.