EasyManua.ls Logo

Kemppi Kempact Pulse 3000 - IGBT Gate Pulse Measurement

Kemppi Kempact Pulse 3000
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18 – Kempact pulse 3000, Kempactcool 10 / 0813 © Kemppi oy
Parameter Name Nr Display 1-MIG Pulsed
MIG
Factory
value
Unit Explanation
PostGasTime 1 PoG X X Curve s PostGas time 0.0…9.9 s
PreGasTime 2 PrG X X Curve s PreGas time, functions by
2T 0.0…9.9 s
HotStartLevel 11 Hot X X 30 % Hot start ratio to welding
power 50…+75%
HotStartTime 2T 12 H2t X X 2 s 2T Hot start timer 0.1-9.9 s
CraterFillLevel 14 CFL X X 30 % Welding end level 10-90 %
CraterFillSlope 15 CFS X X 1 s/10m Wire slowing-down
1…20 s/10m
CreepStartLevel 17 CSL X X Syn Wire speed start value
10…90
CreepStartSlope 18 CSS X X 0 s/10m Wire speed up time
0.1…5 s/10m
DoubleFrequency 21 dFr X Curve Hz Double pulse frequency
control 0.4…8.0 Hz
DoubleAmpiltude 22 dA X Curve m/min Double pulse power
variation
control 0.1…3.0 m/min
StartPower 31 StP X X 0 Start power control
-9…0…+9
PulseCurrent 33 PuC X 0 % Pulse top current control
10…+15%
ArcLength
AdjRange
41 ALr X X 0 % Arc length adjustment
range 50…+75%
Calibration 42 CAL X X 1 V/100A Setting mid value of arc
length ne adjustment
0.0…10.0 V/100A
WFS
51 FS 18 m/min Wire feed maximum
18 or 25 m/min
Gun 53 Gun On liquidcooled thermal
protection on/off
GunRemote 54 GrE On Disabling of gun remote
control automatic
identication
Display reset
time
81 dLY X X 5 s 1...20 s
PRG INFO - feeld
selection
82 diS X X 1 1,2,3
Restore 99 FAC X OFF Restoring factory settings
(OFF=no reset,
Pan=panel and setup
ALL= also memory
channels)
Setup functions on pulse panel

Other manuals for Kemppi Kempact Pulse 3000

Related product manuals