(No.RA018<Rev.002>)1-49
[Analog
Narrow]
*2
1) Adj item:
[An ADEV]
Adjust:[****]
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
Adjust:[****]
PTT : ON
Press [ ] key to
store the adjust-
ment value.
1) Adj item:
[Maxmum Devia-
tion (Analog Nar-
row)]
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
Devia-
tion
meter
Oscil-
lo-
scope
Panel ANT Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[],
[]
Write fixed value “503”
for each adjustment
point. Transmit at each
adjustment point and
check that the deviation
is between 2050Hz and
2150Hz.
Deviation meter
LPF: 15kHz
HPF: OFF
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
2050~2150Hz
[PC test
mode]
Press [Apply
All] button to
store the
adjustment
value after all
adjustment
points have
been adjusted.
*2 : Refer to the “4.9.1 Necessary Deviation adjustment item for each signaling and mode” table.
Regarding Maximum Deviation (Analog), it is common with the adjustment of all analog signalings.
8. P25
High
Devia-
tion
1) Adj item:
[P1 PDEV]
Adjust:[****]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
Adjust:[****]
PTT : ON
Press [ ] key to
store the adjust-
ment value.
1) Adj item:
[P25 High Devia-
tion]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
Devia-
tion
meter
Oscil-
lo-
scope
Panel ANT Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[],
[]
Write fixed value “505”
for each adjustment
point. Transmit at each
adjustment point and
check that the deviation
is between 2771Hz and
2883Hz.
Deviation meter
LPF: 3kHz
HPF: OFF
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
2771~2883Hz
[PC test
mode]
Press [Apply
All] button to
store the
adjustment
value after all
adjustment
points have
been adjusted.
9. P25
H-CPM
Devia-
tion
1) Adj item:
[P2 P2DEV]
Adjust:[****]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
Adjust:[****]
PTT : ON
Press [ ] key to
store the adjust-
ment value.
1) Adj item:
[P25 H-CPM Devi-
ation]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
Devia-
tion
meter
Oscil-
lo-
scope
Panel ANT Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[],
[]
Write fixed value “485”
for each adjustment
point. Transmit at each
adjustment point and
check that the deviation
is between 3090Hz and
3215Hz.
Deviation meter
LPF: 3kHz
HPF: OFF
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
3090~3215Hz
[PC test
mode]
Press [Apply
All] button to
store the
adjustment
value after all
adjustment
points have
been adjusted.
Item Condition Measurement Adjustment Specifica-
tions
/Remarks
Panel tuning
mode
PC test mode Test-
equip-
ment
Unit Ter-
minal
Unit Parts Method

Table of Contents

Other manuals for Kenwood NX-5200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kenwood NX-5200 and is the answer not in the manual?

Kenwood NX-5200 Specifications

General IconGeneral
IP RatingIP67
Zones128
GPSYes
BluetoothYes
Voltage Range7.5V DC ±20%
Operating Temperature-30°C to +60°C
Frequency Range136-174 MHz
Battery Life14 hours (Digital mode)
Digital ProtocolNXDN, DMR
DisplayLCD