1-50 (No.RA018<Rev.002>)
10.
NXDN
High
Devia-
tion
[NXDN
Narrow]
1) Adj item:
[Nn NDEV]
Adjust:[****]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
Adjust:[****]
PTT : ON
Press [ ] key to
store the adjust-
ment value.
1) Adj item:
[NXDN High Devia-
tion (NXDN Nar-
row]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
Devia-
tion
meter
Oscil-
lo-
scope
Panel ANT Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[],
[]
Write fixed value “505”
for each adjustment
point. Transmit at each
adjustment point and
check that the deviation
is between 2995Hz and
3117Hz.
Deviation meter
LPF: 3kHz
HPF: OFF
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
2995~3117Hz
[PC test
mode]
Press [Apply
All] button to
store the
adjustment
value after all
adjustment
points have
been adjusted.
[NXDN
Very
Narrow]
1) Adj item:
[Nv NDEV]
Adjust:[****]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
Adjust:[****]
PTT : ON
Press [ ] key to
store the adjust-
ment value.
1) Adj item:
[NXDN High Devia-
tion (NXDN Very
Narrow]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
Devia-
tion
meter
Oscil-
lo-
scope
Panel ANT Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[],
[]
Write fixed value “495”
for each adjustment
point. Transmit at each
adjustment point and
check that the deviation
is between 1331Hz and
1363Hz.
Deviation meter
LPF: 3kHz
HPF: OFF
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
1311~1363Hz
[PC test
mode]
Press [Apply
All] button to
store the
adjustment
value after all
adjustment
points have
been adjusted.
11. QT
Devia-
tion *3
[Analog
Wide]
1) Adj item:
[Aw QT]
Adjust:[****]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
Adjust:[****]
PTT : ON
Press [ ] key to
store the adjust-
ment value.
1) Adj item:
[QT Deviation (An-
alog Wide)]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
Devia-
tion
meter
Oscil-
lo-
scope
Panel ANT Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[],
[]
Write the value as fol-
lowings. 513 (Reference
value)
0.75kHz±0.05
kHz
Item Condition Measurement Adjustment Specifica-
tions
/Remarks
Panel tuning
mode
PC test mode Test-
equip-
ment
Unit Ter-
minal
Unit Parts Method

Table of Contents

Other manuals for Kenwood NX-5200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kenwood NX-5200 and is the answer not in the manual?

Kenwood NX-5200 Specifications

General IconGeneral
IP RatingIP67
Zones128
GPSYes
BluetoothYes
Voltage Range7.5V DC ±20%
Operating Temperature-30°C to +60°C
Frequency Range136-174 MHz
Battery Life14 hours (Digital mode)
Digital ProtocolNXDN, DMR
DisplayLCD

Related product manuals