EasyManuals Logo

Kenwood NX-5200 Service Manual

Kenwood NX-5200
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #90 background imageLoading...
Page #90 background image
1-90 (No.RA018<Rev.002>)
5. Open
Squelch
[Analog
Wide 5k]
1) Adj item:
[Aw SQL]
Adjust:[***]
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
SSG output:
12dB SINAD level
at Analog Narrow
-3dB
(MOD: 1kHz/
±3kHz)
1) Adj item:
[Open Squelch (An-
alog Wide 5k)]
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
SSG output:
12dB SINAD level at
Analog Narrow -3dB
(MOD: 1kHz/±3kHz)
SSG
Distor-
tion
meter
Oscillo-
scope
Panel ANT
Uni-
versal
con-
nector
Panel [Panel tuning mode]
After input signal from
SSG, press [ ] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
[Analog
Wide 4k]
1) Adj item:
[As SQL]
Adjust:[***]
2) Adj item:
[Low1]
[Low5]
[Center3]
[High2]
[High6]
SSG output:
12dB SINAD level
at Analog Narrow
-3dB
(MOD: 1kHz/
±2.4kHz)
1) Adj item:
[Open Squelch (An-
alog Wide 4k]
2) Adj item:
[Low1]
[Low5]
[Center3]
[High2]
[High6]
SSG output:
12dB SINAD level at
Analog Narrow -3dB
(MOD: 1kHz/
±2.4kHz)
SSG
Distor-
tion
meter
Oscillo-
scope
Panel ANT
Uni-
versal
con-
nector
Panel
[Panel tuning mode]
After input signal from
SSG, press [ ] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
[Analog
Narrow]
1) Adj item:
[An SQL]
Adjust:[***]
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
SSG output:
12dB SINAD level
at Analog Narrow
-3dB
(MOD: 1kHz/
±1.5kHz)
1) Adj item:
[Open Squelch (An-
alog Narrow)]
2) Adj item:
[Low1]
[Low3]
[Center2]
[High1]
[High3]
SSG output:
12dB SINAD level at
Analog Narrow -3dB
(MOD: 1kHz/
±1.5kHz)
SSG
Distor-
tion
meter
Oscillo-
scope
Panel ANT
Uni-
versal
con-
nector
Panel [Panel tuning mode]
After input signal from
SSG, press [ ] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
Item Condition Measurement Adjustment Specifi-
cations
/Remarks
Panel tuning mode PC test mode Test-
equip-
ment
Unit Ter-
minal
Unit Parts Method

Table of Contents

Other manuals for Kenwood NX-5200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kenwood NX-5200 and is the answer not in the manual?

Kenwood NX-5200 Specifications

General IconGeneral
IP RatingIP67
Zones128
GPSYes
BluetoothYes
Voltage Range7.5V DC ±20%
Operating Temperature-30°C to +60°C
Frequency Range136-174 MHz
Battery Life14 hours (Digital mode)
Digital ProtocolNXDN, DMR
DisplayLCD

Related product manuals