1-90 (No.RA018<Rev.002>)
5. Open
Squelch
[Analog
Wide 5k]
1) Adj item:
[Aw SQL]
Adjust:[***]
2) Adj item:
[Low1]→
[Low3]→
[Center2]→
[High1]→
[High3]
SSG output:
12dB SINAD level
at Analog Narrow
-3dB
(MOD: 1kHz/
±3kHz)
1) Adj item:
[Open Squelch (An-
alog Wide 5k)]
2) Adj item:
[Low1]→
[Low3]→
[Center2]→
[High1]→
[High3]
SSG output:
12dB SINAD level at
Analog Narrow -3dB
(MOD: 1kHz/±3kHz)
SSG
Distor-
tion
meter
Oscillo-
scope
Panel ANT
Uni-
versal
con-
nector
Panel [Panel tuning mode]
After input signal from
SSG, press [ ] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
[Analog
Wide 4k]
1) Adj item:
[As SQL]
Adjust:[***]
2) Adj item:
[Low1]→
[Low5]→
[Center3]→
[High2]→
[High6]
SSG output:
12dB SINAD level
at Analog Narrow
-3dB
(MOD: 1kHz/
±2.4kHz)
1) Adj item:
[Open Squelch (An-
alog Wide 4k]
2) Adj item:
[Low1]→
[Low5]→
[Center3]→
[High2]→
[High6]
SSG output:
12dB SINAD level at
Analog Narrow -3dB
(MOD: 1kHz/
±2.4kHz)
SSG
Distor-
tion
meter
Oscillo-
scope
Panel ANT
Uni-
versal
con-
nector
Panel
[Panel tuning mode]
After input signal from
SSG, press [ ] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
[Analog
Narrow]
1) Adj item:
[An SQL]
Adjust:[***]
2) Adj item:
[Low1]→
[Low3]→
[Center2]→
[High1]→
[High3]
SSG output:
12dB SINAD level
at Analog Narrow
-3dB
(MOD: 1kHz/
±1.5kHz)
1) Adj item:
[Open Squelch (An-
alog Narrow)]
2) Adj item:
[Low1]→
[Low3]→
[Center2]→
[High1]→
[High3]
SSG output:
12dB SINAD level at
Analog Narrow -3dB
(MOD: 1kHz/
±1.5kHz)
SSG
Distor-
tion
meter
Oscillo-
scope
Panel ANT
Uni-
versal
con-
nector
Panel [Panel tuning mode]
After input signal from
SSG, press [ ] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
Item Condition Measurement Adjustment Specifi-
cations
/Remarks
Panel tuning mode PC test mode Test-
equip-
ment
Unit Ter-
minal
Unit Parts Method