ES749 Flow Computer
45
Select the unit for volumetric owrate.
Note:
The unit selected here also applies to the following:
Zero and full scale value for current
Relay setpoints
Selection:
The available selections will change depending on the ow equation
selected.
bbl/time base, gal/time base, l/time base, hl/time base, dm
3
/
time base, ft
3
/time base, m
3
/time base, acf/time base, igal/
time base
All units listed above apply to the actual volume measured under
operating conditions.
Display: ft3/h
VOLUME FLOW UNIT
Select the unit for uncorrected volume totalizer.
Note:
The unit selected here also applies to the following:
Pulse value for pulse output
Relay setpoints
Selection:
The available selections will change depending on the ow equation
selected.
bbl, gal, l, hl, dm
3
, ft
3
, m
3
, acf, igal
All units listed above apply to the actual volume measured under
operating conditions.
Display: ft3
VOLUME TOTAL UNIT
VOLUME FLOW UNIT
VOLUME TOTAL UNIT
SYSTEM UNITS
6.6
SYSTEM
UNITS
(Continued)