How to Pair a New RFID Tag by Panel
Go to Menu>Parts>RFID>Add and enter
Synchronizing is displayed, the
panel goes into the sniffer mode
and count down the pairing time
remaining .
Tap the RFID Tag on the panel.
As the serial number of RFID Tag
is added to the panel, ‘Leaning OK
will be displayed.
The panel will display ‘Device code
has been learnt if serial number of
RFID Tag have been learned.
Go to Menu>Parts>RFID>Delete to delete the RFID Tag specified
by serial number .
How to pair a new wireless siren by Panel
Go to Menu>Parts>Siren Learn
SET
O
N
OF
F
DC 5
V
Go to Menu>Parts>RFID>Delete All to delete all the RFID Tags.
Press and hold the SET button of
the siren until you hear two beeps,
then the siren goes into the Sniffer
mode and the light ring blinks quickly.
Press button on the panel within
6 seconds. The panel displays
Learn Signal Sent and sends
a transmission signal to the siren.
The siren gives a four beeps of
successful indication
If you want to unbind the wireless siren from the panel, press
and hold the SET button of the siren until you hear three beeps.