Test Description Instrument settings
Voltage Programming & Readback, Zero Voltage (V
0
) 0 V 2 A
Voltage Programming & Readback, Maximum Voltage (V
max
) 20 V 2 A
CV Load Regulation, Line Regulation, Ripple and Noise 20 V 2 A
Transient Response 20 V 1 Ato 2 A
Current Programming & Readback, Zero Current (I
0
) 0 A 20 V
Current Programming & Readback, Maximum Current (I
max
) 2 A 20 V
CC Load Regulation, Line Regulation, Ripple and Noise 2 A 20 V
Keysight E36100B Series Operating and Service Guide 81