Millimeter Module Cable Options ( for N5261A and N5262A Millimeter Test
Set Controller)
Option 501: A set of 4 foot cables for connection of a module to the test
set controller.
Option 502: A set of 2 meter cables for connection of module to the test
set controller.
Option 503: A set of 3 meter cables for connection of module to the test
set controller.
Option 505: A set of 5 meter cables for connection of module to the test
set controller.
IF access (Option H11)
Provides hardware to enable antenna, point-in-pulse, and broadband millimeter-
wave measurements to 110 GHz. For each of the MW PNA’s measurement receivers,
IF gates (enabled with pulsed measurement capability, Option 008) and external
IF inputs are added. In addition, access to the PNA’s internal RF and LO source is
provided for remote mixing applications. For basic antenna measurements, only Op-
tion H11 is necessary. Pulsed-antenna applications also require the pulsed measure-
ment capability (Option 008). Broadband measurements to 110 GHz, also requires an
N5260A.
Use external IF access for up to 20 dB more sensitivity when making antenna
measurements with a remote mixing conguration
Add Option 008 (Pulsed-RF Measurement Capability) to enable advanced pulsed
measurements
Upgrade an E8361C with Option H11 to a broadband (10 MHz to 110 GHz) VNA
system simply by purchasing an N5260A controller test set with Option 110, 120,
or 130.
Time-domain capability (Option 010)
Used for viewing reection and transmission responses in time or distance domain.
Congurable test set (Option 014)
Provides six front panel access loops. The loops provide access to the signal path
between (a) the source output and the reference receiver, (b) the source output and
directional coupler thru arm and (c) the coupled arm of the directional coupler and
the port receiver.
Extended power range and bias tees (Option UNL)
1
A 50 dB step attenuator and bias-tee set is inserted between the source and test
port one and another set between the source and test port two.
Frequency offset (Option 080)
1
This option enables the PNA Series microwave network analyzers to set the source
frequency independently from where the receivers are tuned.
1. These options apply to the E8361C and
are limited to 67 GHz frequency range.
Option Descriptions
21 | Keysight | Antenna Test – Selection Guide

Other manuals for Keysight PNA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight PNA Series and is the answer not in the manual?

Keysight PNA Series Specifications

General IconGeneral
Number of Ports2, 4
Impedance50 Ω
Output Power Range-55 dBm to +13 dBm (varies by model)
DimensionsVaries by model
WeightVaries by model
Power Requirements100-240 VAC, 50/60 Hz