3 Programming the Analyzer
List of SCPI Commands
[:SENSe]:FSCan:SCAN[1]|2|...|10:POWer:GAIN:BAND?
[:SENSe]:FSCan:SCAN[1]|2|...|10:POWer:GAIN[:STATe] ON | OFF | 1 | 0
[:SENSe]:FSCan:SCAN[1]|2|...|10:POWer:GAIN[:STATe]?
[:SENSe]:FSCan:SCAN[1]|2|...|10:PRBW <integer>
[:SENSe]:FSCan:SCAN[1]|2|...|10:PRBW?
[:SENSe]:FSCan:SCAN[1]|2|...|10:RULes PRBW | LPCT
[:SENSe]:FSCan:SCAN[1]|2|...|10:RULes?
[:SENSe]:FSCan:SCAN[1]|2|...|10:STARt <freq>
[:SENSe]:FSCan:SCAN[1]|2|...|10:STARt?
[:SENSe]:FSCan:SCAN[1]|2|...|10:STATe ON | OFF | 1 | 0
[:SENSe]:FSCan:SCAN[1]|2|...|10:STATe?
[:SENSe]:FSCan:SCAN[1]|2|...|10:STEP <freq>
[:SENSe]:FSCan:SCAN[1]|2|...|10:STEP?
[:SENSe]:FSCan:SCAN[1]|2|...|10:STEP:AUTO ON | OFF | 1 | 0
[:SENSe]:FSCan:SCAN[1]|2|...|10:STEP:AUTO?
[:SENSe]:FSCan:SCAN[1]|2|...|10:STIMe <time>
[:SENSe]:FSCan:SCAN[1]|2|...|10:STIMe?
[:SENSe]:FSCan:SCAN[1]|2|...|10:STIMe:AUTO ON | OFF | 1 | 0
[:SENSe]:FSCan:SCAN[1]|2|...|10:STIMe:AUTO?
[:SENSe]:FSCan:SCAN[1]|2|...|10:STOP <freq>
[:SENSe]:FSCan:SCAN[1]|2|...|10:STOP?
[:SENSe]:FSCan:SCAN:TDOMain:TYPE IMPulse | CWAve
[:SENSe]:FSCan:SCAN:TDOMain:TYPE?
[:SENSe]:FSCan:SCAN[1]|2|...|10:TIME <time>
[:SENSe]:FSCan:SCAN[1]|2|...|10:TIME?
[:SENSe]:FSCan:SCAN[1]|2|...|10:TIME:AUTO ON | OFF | 1 | 0
[:SENSe]:FSCan:SCAN[1]|2|...|10:TIME:AUTO?
[:SENSe]:FSCan:SCAN:TYPE SMOoth | DISCrete | TDOMain
[:SENSe]:FSCan:SCAN:TYPE STEPped | SWEpt | TDOMain
[:SENSe]:FSCan:SCAN:TYPE?
[:SENSe]:FSCan:SEARch:MODE PONLy | PLIMits | SLIMits
[:SENSe]:FSCan:SEARch:MODE?
[:SENSe]:FSCan:SEARch:PEAK:COUNt <integer>
[:SENSe]:FSCan:SEARch:PEAK:COUNt?
[:SENSe]:FSCan:SEARch:PEAK:COUNt:STATe ON | OFF | 1 | 0
[:SENSe]:FSCan:SEARch:PEAK:COUNt:STATe?
[:SENSe]:FSCan:SEARch:SUBRange:COUNt <integer>
[:SENSe]:FSCan:SEARch:SUBRange:COUNt?
[:SENSe]:FSCan:SEQuence SCAN | SEARch | SSAMeasure | SASearch | SAMeasure
| REMeasure
[:SENSe]:FSCan:SEQuence?
[:SENSe]:FSCan:SEQuence:REMeasure CURRent | MARKed | ALL
[:SENSe]:FSCan:SEQuence:REMeasure?
[:SENSe]:FSCan:SLISt:COMMent <integer>, "string"
[:SENSe]:FSCan:SLISt:COMMent? <integer>
[:SENSe]:FSCan:SLISt:COUPle:METer ON | OFF | 1 | 0
[:SENSe]:FSCan:SLISt:COUPle:METer?
[:SENSe]:FSCan:SWEep:COUNt <integer>
[:SENSe]:FSCan:SWEep:COUNt?
[:SENSe]:METer:ATTenuation:AUTO ON | OFF | 1 | 0
[:SENSe]:METer:ATTenuation:AUTO?
[:SENSe]:METer:ATTenuation:PROTection ON | OFF | 1 | 0
[:SENSe]:METer:ATTenuation:PROTection?
EMI Receiver Mode Reference 89