15
7 8 96
10
Closed
Inlet
PPF Sedi-
ments
CTO Precar-
bon
CTO Postcar-
bon
Measuring
cup
Closed
Open
Open
Open
• Once the assembly is installed, keep the new manual
inlet valve closed and open the inlet valve connected to
the wall adapter (7). The measuring cup must be empty.
• Pour 0.25 liters of Oxygenated Water into the dosing
vessel interspersed at the equipment inlet (8). Thread
the glass correctly to its head.
• The manual inlet valve and the tap must be closed.
Connect the equipment to the power supply.
• Open the water inlet stopcock to the equipment and
the tap, allowing it to start its operation and allowing
it to breathe the Oxygenated Water into it. Fill a 1L jug
with tap water. Before closing the tap, close the inlet
valve again to lower the pressure. Refill the dispenser
with 0.25l of hydrogen peroxide and drain 1 liter more
water. Turn off the tap. At this time the entire circuit
contains sanitizing liquid.
• After 10 mins. open the dispensing tap (9) and let the
water circulate for 5 mins.
• Empty the measuring cup. Before opening it, have a
container at your fingertips where you can empty it, as
it can be filled with water.
Open
RO Mem-
brane