11
IN/FEED
DRAIN
3/8”
RO
3/8”
Hydraulic scheme
1/4”
3/8”
3/8”
1/4”
• After commissioning, open the tap and with the co-
rresponding meter of the parameter of interest, mea-
sure in the water dispensed by the tap and slowly and
progressively open the mixing valve until the desired
parameter is achieved.
• The water dispensed must comply with the drinking
requirements established by European Directive 98/83
or corresponding national legislation that transposes it.
4.2. INSTALLATION OF FILTERS
• Remove the filter cartridges from their cardboard packa-
ging. The number of each cartridge must match that of the
housing
• IInsert the PPF 1 sediment filter into the housing 1. The
triangle icon on the filter cover should point to the icon
• Press the filter firmly and rotate it 90º clockwise.
Match the triangle icon with the icon
• Follow the steps above to install the carbon prefilter,
membrane and carbon postfilter.