EasyManua.ls Logo

KNF N838 E Series - Installation and Connection; Installing the Pump

KNF N838 E Series
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation and connection
Diaphragm pump N838_E
20
Translation of Original Operating and Installation Instruction, KNF
347394-347605 09/23
6 Installation and connection
Only install the pumps in accordance with the operating pa-
rameters and conditions described in Chapter 3 Technical
data [}12].
à
Observe the safety instructions (see Chapter 2 Safety
[}6]).
NOTICE
Damage due to particulate entering
your pump
à Take protective measures against
allowing particulate entering the
pump.
DANGER
Risk of dangerous gas mixtures during
pump operation
Depending on the medium being trans-
ferred, breakage of the media-contact-
ing components can result in a danger-
ous mixture if the medium mixes with
the air in the compressor housing or
the surroundings.
à Before using a medium, check the
compatibility of the media-con-
tacting components (see 3 Tech-
nical data [}12]) with the
medium.
6.1 Installing the pump
à
Store the pump at the installation site to allow it to adapt
to the ambient temperature before installation (condensa-
tion must not be allowed to form).
Mounting dimen-
sions
à
For mounting dimensions, see the following illustrations:

Related product manuals