16 A-61730 August 2012
Place the flag in the U-Shaped sensor until the top of the
flag is flush. Be sure the new flag is in the correct position
with the word “UP” facing towards you.
Lower the retention lever. Make sure that when the
skimmer assembly is raised and lowered manually, that
the flag raises and lowers with it.
8. Using your left hand, pull the spring-loaded, green lever toward the
left. Secure it behind the lock pin.
9. Insert the skimmer assembly into position, placing the right side in
first.
10.Slowly release the spring-loaded, green lever back to its original
position so that it secures the skimmer assembly.
11. Lower the auto/manual feed lever to the ‘A’ position.
12.Close the scanner transport cover.
13.Power on the scanner.
14.Boot up the host PC.
15.Clean the skimmer rollers.