26
13Guideline to Select the Guide Pipe
AV
AVS
AVSS
Sq
Final OD
Guide Pipe
Sq
Final OD
Guide Pipe
Sq
Final OD
Guide Pipe
0.3
0.5
0.85
1.25
1.8mm
2.2mm
2.4mm
2.7mm
2.5 φ
φ
φ
φ
0.5
0.85
1.25
2.0mm
2.2mm
2.5mm
2.5 φ
2.5 φ
φ
0.3
0.5
0.85
1.25
1.5mm
1.7mm
1.9mm
2.2mm
φ
φ
2.5 φ
2.5 φ
CAVUS
KV,KHV,KVH
VSF,HVSF
Sq
Final OD
Guide Pipe
Sq
Final OD
Guide Pipe
Sq
Final OD
Guide Pipe
0.3
0.5
0.85
1.1mm
1.3mm
1.5mm
1.5 φ
2 φ
2 φ
0.3
0.5
0.75
1.25
1.5mm
1.9mm
2.1mm
2.7mm
φ
2.5 φ
2.5 φ
φ
0.5
0.75
2.5mm
2.7mm
φ
φ
UL1571
UL1015
UL1007
AWG
Final OD
Guide Pipe
AWG
Final OD
Guide Pipe
AWG
Final OD
Guide Pipe
28
26
24
22
0.88mm
mm
1.11mm
1.30mm
1.5 φ
1.5 φ
1.5 φ
2 φ
28
26
24
22
20
18
2.00mm
2.10mm
2.23mm
2.38mm
2.57mm
2.83mm
2.5 φ
2.5 φ
2.5 φ
φ
φ
φ
28
26
24
22
20
18
16
1.20mm
1.30mm
1.43mm
1.58mm
1.77mm
2.03mm
2.35mm
1.5 φ
1.5 φ
φ
φ
φ
2.5 φ
φ
CautionDepending on the manufacturer or form of the wire, it may be appropriate to use a
guide pipe whose size is larger than the one on the list.
14
MDU Board
MDU board controls each motor.
Make sure to turn off the power of the machine when replacing the MDU Board.
The voltage is left for several minutes even if the power is turned OFF. Wait more than 5
minutes before exchanging the MDU board.
For right roller
For cutter
For left roller