6
4.Operation Panel
《Basics》 Screen
Standard Processing When not selecting ④~⑦ on the 《Motion》 Screen(P.11).
①《Front Strip Length》:Setting of the stripping length of the front
side insulation.
②《Front Half Strip Length》:Setting of the half stripping length of
the front side.
③《Total Length》:Setting of the cutting length of the wire.
④《Rear Strip Length》:Setting of the stripping length of the rear side
insulation.
⑤《Rear Half Strip Length》:Setting of the half stripping length of rear side.
⑥《Core Diameter》:Depth of the blade when stripping the wire. (See P,8)
⑦《Blade Move Back》:Setting of the blade back when stripping
the insulator. (See P,9)
⑧《Total Length Correction》:When “Set Total Length” and “Actually processed total length”
are different, correct it here.
0:No correction
For Example)
Set Total Length
Actual Total Length
Correctionn
Amount
○
a
1000mm
997mm
3mm
Input
3
○
b
1000mm
1005mm
-5mm
Input
-5
⑨《-》:Minus key When correcting the numerical value adversely at ⑧, use this key.
《-1》:Minus 1 key. The current number (quantity of wire to be processed) will be
reduced by -1.
⑩《Setting Pieces》:Setting of the pieces to be processed.
⑪《Current Pieces》:Processed Pieces of the wire.
During processing, number of the 《 Current Pieces 》 ( processed pieces ) is
increasing every second.
When you want to clear the displayed number to “0”, press 《Current Pieces》 [0]
[SET].
Unit: 0.1mm
Unit: 0.01mm