3.How to attach and use CN-03
(
Straightening machine
)
・How to Mount
Mount the straightening machine with cap
screws as the left picture.
・How to Use
Push ○
a
levers right and left to remove the lock and straightening part is widened.
Let the wire through and then press ○
b
.
Adjust the strong and weak of the straightening part by turning the ○
c
knobs.
Caution:If the straightening part is too narrower
or stronger, the total length of the processed wire
will be shorter.
How to connect air tube
・The slug removeable air is made to work with the power of the air. Let through the regulator
from the compressor to provided coupler to connect to the insertion opening on the rear side
of the main body.
A suitable numerical value for the air pressure is 0.4~0.5MPa.
Do not input a pressure value higher than 0.65MPa.