EasyManuals Logo
Home>Kohler>Controller>Decision-Maker 3000

Kohler Decision-Maker 3000 Operation

Kohler Decision-Maker 3000
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
TP-6694 9/20 27
Event Log Menu
This menu allows the user to review up to 1000 entries of system events including shutdown faults, warning faults, and status
events. See the section titled: Controller Fault Diagnostics for a list of the items that appear on the Event Log.
Volt Select Menu
Note:
The generator set must be stopped before changing the voltage selection.
This menu allows the user to readily change controller voltage settings. The volt select feature is typically used in towable or
temporary applications.
Note:
The volt select menu requires initial activation by SiteTech™ software. In SiteTech™ software, select True to activate the volt
select menu.
Note:
The generator set output leads require voltage reconnection if the generator set does not have a voltage selector switch installed.
With the generator set stopped, go to the Volt Select menu. Then push and hold the pushbutton/rotary selector dial until the
voltage selection starts to flash. Volt selection is now available. Scroll to the desired voltage and momentarily press the
pushbutton/rotary selector dial to confirm the voltage selection.
The displays for Volt Select appear as shown in the following list.
120/240 V 1 Ph
120/208 V 3 Ph
139/240 V 3 Ph
277/480 V 3 Ph
120/240 V 3 Ph

Table of Contents

Other manuals for Kohler Decision-Maker 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler Decision-Maker 3000 and is the answer not in the manual?

Kohler Decision-Maker 3000 Specifications

General IconGeneral
BrandKohler
ModelDecision-Maker 3000
CategoryController
LanguageEnglish

Related product manuals