Error code
SPN FMI Designation
516512 31 Starters - Not connected in the output 2 to engine control unit
1076 6 Volume control valve - Critical high output current
1076 0 Volume control valve - Critical overcurrent
1076 1 Volume control valve - Critical undercurrent
516251 11 Volume control valve - Current remains above the set point
516252 11 Volume control valve - Current remains below the set point
516330 11 Volume control valve - Electrical error
1076 5 Volume control valve - Open circuit
516253 11 Volume control valve - PWM signal - High limit reached
516254 11 Volume control valve - PWM signal - Plausibility error
1076 11 Volume control valve - Short circuit load
1076 3 Volume control valve - Short circuit to battery high side
516328 3 Volume control valve - Short circuit to battery low side
1076 4 Volume control valve - Short circuit to ground high side
516329 4 Volume control valve - Short circuit to ground low side
516255 6 Volume control valve 2 - Critical high output current
516255 0 Volume control valve 2 - Critical overcurrent
516255 11 Volume control valve 2 - Critical undercurrent
516256 11 Volume control valve 2 - Current remains above the set point
516257 11 Volume control valve 2 - Current remains below the set point
516336 11 Volume control valve 2 - Electrical error
516255 5 Volume control valve 2 - Open circuit
516258 11 Volume control valve 2 - PWM signal - High limit reached
516259 11 Volume control valve 2 - PWM signal - Plausibility error
516255 11 Volume control valve 2 - Short circuit load
516255 3 Volume control valve 2 - Short circuit to battery high side
516336 3 Volume control valve 2 - Short circuit to battery low side
516255 4 Volume control valve 2 - Short circuit to ground high side
516336 4 Volume control valve 2 - Short circuit to ground low side
5386 6 Wastegate valve - Critical high output current
5386 11 Wastegate valve - Electrical error
5386 5 Wastegate valve - Open circuit
516318 31 Wastegate valve - Short circuit load
5386 3 Wastegate valve - Short circuit to battery high side
516266 3 Wastegate valve - Short circuit to battery low side
5386 4 Wastegate valve - Short circuit to ground high side
516266 4 Wastegate valve - Short circuit to ground low side
97 5 Water in fuel sensor - Open circuit
KD62V12 33521030301_8_1 EN_US 2022-09
© 2022 by Kohler Co. All rights reserved.
181

Table of Contents

Other manuals for Kohler KD62V12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler KD62V12 and is the answer not in the manual?

Kohler KD62V12 Specifications

General IconGeneral
BrandKohler
ModelKD62V12
CategoryEngine
LanguageEnglish

Related product manuals