5
INFORMATION ABOUT MAINTENANCE
EN 44
5.13 Engine starting after storage
1.
Remove the protective sheet.
2.
Use a cloth soaked in degreasing product to remove the protective treatment from the external
parts.
3.
Inject lubricating oil (no more than 2 cm3) into the intake ducts.
4.
Refill the tank with fresh fuel.
5.
Make sure that the oil and the coolant are up to the MAX level.
6.
Proceed with the disposal of the AdBlue contained in the tank; replace the AdBlue pump filter
and wash the AdBlue tank/circuit with hot distilled water.
7.
Check the AdBlue injector at an authorized Kohler workshop.
8.
Start the engine and keep it idle at minimum speed for a two about minutes.
9.
Bring the engine to 75% of MAX rated speed for 5 to 10 minute.
10.
Stop the engine while the oil is still hot ( Par. 6.1 ), discharge the protective oil in a suitable
container.
Warning:
•
Over time, lubricants and filters lose their properties, so it is important consider whether
they need replacing, also based on the criteria described in Tab. 5.2 .
11.
Replace the filters (air, oil, fuel) with original spare parts.
12.
Pour new oil ( Par. 4.5 ) up to the MAX level.
13.
Empty the cooling circuit completely and pour in the new coolant up to the MAX level ( Par. 4.6 ).