EasyManua.ls Logo

Kohler KDI 3404TCR-SCR

Kohler KDI 3404TCR-SCR
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INFORMATION ABOUT REPLACEMENTS
6
51
EN
6.5 Replacement of AdBlue® filter
Warning
Before proceeding with operation, read Par. 3.2.2
Do not lubricate gaskets A with oil or fuel.
Filter D includes gaskets A in the package.
Avoid any type of contamination during replacement.
Before starting any operations, make sure the key on the machine’s panel is OFF and the
AdBlue® pump has executed the circuit emptying operation.
1.
Loosen cap B.
6.11
2.
Remove cap B and extract filter bracket C.
3.
Extract filter D.
4.
Use warm AdBlue® to clean the seat of filter D on
pump E if impurities are detected.
5.
Lubricate the A gaskets with AdBlue® or distilled
water.
6.
Place the filter bracket C together with filter D inside
pump E.
7.
Tighten cap B (tightening torque of 20 Nm).
6.12

Table of Contents