Proc. 3: 2-601 Calibration with the 110% load (≥ P2.12).
Proc. 4: 2-645 Calibration with the 125% load (≥ P2.12)
Continue on step a1, a2, a3 or a4 according to the weight of the test load.
a1) Enter value 2-611 at password_2 to calibrate the load sensor with the rated
load of the hoist.
a2) Enter value 2-622 at password_2 to calibrate the load sensor with a test load
of 50-99 % of the rated load of the hoist.
Calculate the percentage value of the test load compared to the rated load of the
hoist. After entered password_2, display will ask for the percentage calculated.
Enter the calculated load percentage value as 'SL xx'.
Example:
A test load of 4000 kg on a 5000 kg hoist gives the percentage value of SL 80
(i.e. 4000 kg / 5000 kg * 100 % = 80 %).
a3) Enter value 2-601 at password_2 to calibrate the load sensor with the 110 %
load.
a4) Enter value 2-645 at password_2 to calibrate the load sensor with the 125 %
load.
3 Select the hoist class
The hoist class, 1Bm - 5m, is entered by the codes given in Table 1. The hoist class can
be seen on the hoist's data label.
a) Enter the valid hoist class code CL 1 - CL 6 (1Bm - 5m) according to Table 1.
Press the blue push-button when the correct hoist class code is displayed.