Page 21
XL
Service Manual
CU1
KCI KONECRANES GROUP
KCI HOISTS CORPORATION
6.2 An error-message (Err_x) is displayed
1 Notice always the first error-message displayed and see Appendix 2.
6.3 The red Temp-light is lit or blinking
1 See Chapter 3.5 to check the normal operation of the overheating protection
circuit. Note the warning and cooling down periods (3 and 2 minutes).
2 Measure the resistance of the thermistors inside the hoisting motor.
a) Normal resistance is 150-1000 ohm (if the motor is overheated the resistance
of the thermistors is more than 4200 ohm)
-If the resistance is out of normal range, check the thermistor wiring and
renew the motor (thermistors) if necessary.
3 Bypass the thermistors by connecting a jumper between CU1:2 and CU1:1.
See note 1!
a) If the alarm disappears after the cooling down and warning periods, check
again the thermistors.
-If the thermistors are OK and the alarm still exists, change the CU1.
b) Remove the jumper between CU1:2 and CU1:1.
6.4 CU1's overload protector prevents lifting below the rated load
(I.e. the red LOAD-light is on with a load below the rated load of the hoist.)
1 See Chapter 3.6 to check the normal operation of overload protection circuit.
2 Make sure that there is no load on the hook and change the CU1 into the load
mode.
a) If the load displayed differs more than ±5% from 'L 00', check the load sensor
and its mounting. Recalibrate the load sensor (i.e. carry out setup routine) if
necessary .
b) If the load displayed is 'L 0' (±5%) as it should be with no load, check the
calibration of the load sensor according to the startup routine and recalibrate
the load sensor if necessary.