APPENDIX 5:How to replace a load sensor (Strain-gauge
APPENDIX 5:How to replace a load sensor (Strain-gauge APPENDIX 5:How to replace a load sensor (Strain-gauge
APPENDIX 5:How to replace a load sensor (Strain-gauge
type)
type)type)
type)
If a strain gauge type of load sensor has to be renewed because of damage, the
CU1 must always be recalibrated with a test load. (Due to the fact that the strain-
gauge load sensors are not identical.)
1 Replace the damaged strain-gauge type of load sensor.
3 If necessary, readjust the load sensor amplifier. (In case of ESD142 or ESD119
amplifier, see Appendix 7).
4 Carry out the CU1 setup routine.