2.3 Regular adjustment flow
2
AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-4
2.3 Regular adjustment flow
2.3.1 Adjustment Timing
When you have changed paper (brand, weight, or size) in a tray
- If you do not change paper in a tray for one or more days, make adjustments before outputting a job
(before the adjustment flow for each job).
2.3.2 Adjustment Order
- With scanner (Original Glass) mounted
- Without scanner (Original Glass) mounted
- With Intelligent Quality Optimizer IQ-501 mounted
Ad-
just-
ment
order
Adjustment item Reference
1 Finely adjust the side guide plates of the paper tray (for PF-707/PF-
707m/PF-602m)
page 2-7
2 [Front] Adjustment page 2-10
3 [Scan Meas.] Adjustment page 2-20
Ad-
just-
ment
order
Adjustment item Reference
1 Finely adjust the side guide plates of the paper tray (for PF-707/PF-
707m/PF-602m)
page 2-7
2 [Front] Adjustment page 2-10
3-a [Rotate/Skew] Adjustment: Prioritizes the accuracy of the image position. page 2-30
3-b [Gap] Adjustment (Back side adjustment): Reduces adjustment items required
to make simple adjustments.
page 2-15
Ad-
just-
ment
order
Adjustment item Reference
1 Finely adjust the side guide plates of the paper tray (for PF-707/PF-
707m/PF-602m)
page 2-7
2 [AutoMeasure] Adjustment page 2-37