EasyManuals Logo

KRAL OMG Series User Manual

KRAL OMG Series
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #43 background imageLoading...
Page #43 background image
14 Troubleshooting
14.2 Troubleshooting
Fault identifica-
tion
Cause Remedy
5 Outgassing
Increase the system pressure.
Reduce the temperature.
5 Pulsations too high
Use another feed pump.
Carry out changes to the system.
5 Back pressure too low
Increase the back pressure.
5 Flow rate fluctuations too high
Ensure a continuous flow rate by taking suitable measures (use of a different pump,
valve, damper, etc.).
-or-
Smoothen the indication. In the process observe the operating instructions of the elec-
tronic equipment.
3 5 Filling amount too low
Use a flowmeter with a suitable size.
Use a flowmeter from a suitable series.
5 Strongly deviating operating data
Use a flowmeter from a suitable series.
Adapt the operating data to the flowmeter.
2 3 4 5 Wear at the measuring unit and bearings
Replace the measuring unit.
Replace the bearings.
Filter out the abrasive materials.
4 5 Sluggishness through deposits
Disassemble the flowmeter and clean it carefully.
2 3 Flow impaired at the system end
Check whether the fluid flows in the system (pump in operation, slide valve opened,
etc.).
Check whether shut-off devices before and after the flowmeter are opened.
2 3 Flowmeter switched to bypass
Switch the flowmeter to through-flow.
Tab.11: Fault table
Operating instructions
OIO 14en-GB Edition 2020-01
43

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KRAL OMG Series and is the answer not in the manual?

KRAL OMG Series Specifications

General IconGeneral
BrandKRAL
ModelOMG Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals