EasyManuals Logo

KRAL OMG Series User Manual

KRAL OMG Series
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
2 Safety
1.4 Associated documents
Meaning Source and possible consequences of non-observance
Risk of slipping Discharging pumped liquid and oils on the foundation or tread surfaces
can cause falls with serious physical injury or death.
Flammable
substances
Discharging pumped liquid and oils can be easily inflammable and can
result in serious burns.
Hot surface Hot surfaces can cause burns.
1.3.3 Symbols in this document
Meaning
Warning personal injury
Safety instruction
Request for action
1.
2.
3.
Multi-step instructions for actions
Action result
Cross-reference
1.4 Associated documents
o Calibration certificate
o Declaration of conformity according to EU Directive 2006/42/EC
o Manufacturer's declaration according to EU Directive 2014/68/EU
o Corresponding operating instructions for accessories
2 Safety
2.1 Proper use
o Flowmeter solely for flow measurement of lubricating liquids that are chemically neutral and that do
not contain gas or solid components.
o Flowmeters require the operation with clean liquids. If coarse soiling, solid particles in the liquid or
abrasive fine particles occur during operation, the flowmeter has to be protected additionally by a
correspondingly dimensioned operating filter in the pipe system.
o Use the flowmeter only within the operating limits specified on the rating plate and in the chapter
"Technical data". Deviating operating data can result in damage to the flowmeter. In the case of op-
erating data that do not agree with the specifications on the rating plate, please contact the manu-
facturer.
o Strong changes in the flow rate (for example rapid shutdown, pulsations, etc.) cause marked pres-
sure differences in the flowmeter and can damage the measuring unit. The pressure loss of the
flowmeter must not exceed the values shown in the chapter "Technical data"
2.2 Foreseeable misuse
o Any use that extends beyond the proper use or any other use is misuse.
o The product is not suitable for pumping liquids outside the operational limits.
o Any bypassing or deactivation of safety equipment during operation is prohibited.
Operating instructions
OIO 14en-GB Edition 2020-01
5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KRAL OMG Series and is the answer not in the manual?

KRAL OMG Series Specifications

General IconGeneral
BrandKRAL
ModelOMG Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals