SID-X1N - Configuring and Maintaining the SID-X1N 17
#
Feature
Function
DIP-switch
6
Switching delay
Selects the time delay before
switching occurs when an
input signal is lost.
Note: The delay is
independent of the input
switching mode
When the input signal is lost but the
cable is not removed:
On0.5 seconds
Off10 seconds
When the cable is removed:
On0.5 seconds
Off3 seconds
7
Output disable
delay
Sets the delay time between
loss of the input signal and
output/PowerConnect
shutdown
On1 minute
Off15 minutes
8
Output Power
Control
Enables/disables the output
power when the input signal is
lost
OnPower is always on
OffPower is disabled when input
signal is lost after delay set by DIP-
switch 7
Note: DIP-switch 2 must be set to ON to enable DIP-switch 3 to control the DVI
audio mode selection.