1 SAFETY INSTRUCTIONS
6
OPTIMASS 6000
www.krohne.com 02/2016 - 4001894004 - MA OPTIMASS 6000 R04 en
1.4 Insulation case
On meters fitted with an insulation case, the case will be filled with one of the following
materials:
Cryogenic meters
Cryogenic metersCryogenic meters
Cryogenic meters (-200°C...+40°C / -364°F...+104°F)
Block grade EPS 1112A (Polystyrene) containing flame retardant additive (FRA)
Standard meters
Standard metersStandard meters
Standard meters (-70°C...+230°C / -94°F...+446°F)
Glass mineral wool
High temperature meters
High temperature metersHigh temperature meters
High temperature meters (-50°C...+400°C / -58°F...+752°F)
Silicon dioxide based mineral wool
Do not open the insulation case. Some, or all, of the above materials can cause:
skin irritation
throat and lung irritation
eye irritation
Install the meter so that water cannot get into the insulation case. Water will damage the
insulation material and reduce performance.
1.5 Pressure Equipment Directive (PED)
To ensure the PED integrity of the meter, you MUST check that the serial numbers on the
converter nameplate and the sensor nameplate are the same.
To comply with the requirements of the Pressure Equipment Directive (PED) the manufacturer
provides all the relevant technical data in the technical data section of this handbook. Secondary
pressure containment is NOT supplied on this meter.
LEGAL NOTICE!
The Pressure Equipment Directive places legal requirements on both the manufacturer and the
end user. Please read this section carefully!