24
6.7 MENU HEATING THE POOL MENU
Pool
Menu
Parameter name Parameter value range Note
Pool
heating loop
operational
mode
ON Turn on
AUTO – Working schedule
OFF Turn off
Setting the
pool loop
temperature
+10 °C to 50 °C Set the desired pool water temperature.
ECO pool mode –10 °C/0 °C ECO lowering the pool temperature by the set value.
COMFORT pool
mode
0 °C /+10 °C
COMFORT raising the pool temperature by the set
value.
Setting the
schedule
1–7 days
0–24 h
Weekly operational schedule.
See chapter 6.8
N
If there is no KT–1/KT–2A thermostat, adaptive regulation is turned off. The KSM regulator calculates the
temperature of the water in the heating loop based on the heating curve with reference temperatures at −15 °C
and +15 °C.
For a constant water temperature in the heating system set the setting at –15 °C and at +15 °C to the same value.
Operating instructions