36
13 REGISTRATION OF THE HEAT PUMP
INTO THE CLOUD
NOTE
See Instructions for Connecting the Web Module
See Instructions for Using the Web Interface.
The service of remote control of the heat pump and
heating system Cloud.KRONOTERM.com is in its
test phase and is completely free.
The information are of exclusively informative
nature and the company Kronoterm d.o.o. does not
guarantee their accuracy. Kronoterm d.o.o. is also
not liable for malfunctions of the system as well
as the potential damage to the customer making
decisions based on this information.
Kronoterm d.o.o. is also not liable for inability of
use, disruptions or malfunctions of the web service
Cloud.KRONOTERM.com.
The service will be available for all until the
company Kronoterm d.o.o. provides it.
In the case where Kronoterm d.o.o. for any reason
temporarily or permanently can no longer provide
the service, the users cannot file any claims arising
from this service in relationship with the company
Kronoterm d.o.o. for setting up another equivalent
service.
The supplier of the service reserves the right to
upgrade the software or make certain adjustments
and settings key for correct and effective operation
of the appliance through the service Home Cloud
without prior notice of the user.
9 SCREEDDRYING PROGRAM
How to set and activate the screed–drying program is
described in the commissioning protocol. During com-
missioning the technician will set it, turn it on, adjust it
if needed, and explain the program to you.
10 HOLIDAY PROGRAM
Activate the program using the KT-2A controller and
setting the holiday duration. The overheating of DHW
activates one day before the end of the program, fol-
lowed by the activation of the heating, cooling or pool
function.
NOTE
The single-day activation of the program does not
have a function.
In the heating mode, the water temperature in
the system drops to the temperature of the anti-
freezing operational mode (AF). Heating of the
DHW and of the pool deactivates.
Cooling, heating of the DHW and the pool
deactivates in the cooling mode.
11 ADDITIONAL HEATER
The KSM regulator allows for 2 additional heaters.
a)Additional heater 1 is a built–in flow through electric
heater that is used if the heat pump has a fault or if
additional heat is needed to heat the system.
b)Additional heater 2 is an external electric heater, oil
or gas heater that can but used as an additional heat
generator in the heating system.
An authorized commissioning technician sets the addi-
tional heater 1 and 2.
Manually turn on the additional heater in the shor-
tcut menu on the KT–2A or on the web and mobile
HomeCloud app. The additional heater turns on auto-
matically if needed.
In backup mode the additional heater 1 is turned on.
12 ANTIFREEZING MODE
If there is a fault and the system is in standby mode,
the heat pump switches to anti–freezing mode. In this
mode water in the heating system is limited to the mi-
nimal temperature.
Additional heater 1 is always used in anti–freezing
mode.
Operating instructions
ADAPT, VERSI, ETERA and WPLV systems
17-19-45-6702-07