6.13 MENU SETTINGS
Setting
Menu
Parameter name Parameter value range Note
Temperature
offset
–4 °C/+4 °C
General rise or fall of parameter NORMAL for heating
loop and buffer tank.
Heating loop
operational
mode
ECO
AUTO
COMFORT
General heating loop operating mode.
Switching
operational
modes
ON – automatic switch
OFF – deactivate automa-
tic switch
ON – automatic switch between heating and cooling.
If you deactivate automatic switching, you must
ensure to manually switch modes.
Screed–drying
ON – Turn on
OFF – Turn off
Program sušenja estriha.
Heating system
pressure
1 – 1.3 bar The heating system pressure can be max. 2.5 bar.
Adaptive curve
loop 1
ON – Turn on
OFF – Turn off
Adaptive regulation automatically turns off if it is set
that way at commissioning.
Adaptive curve
loop 2
ON – Turn on
OFF – Turn off
Adaptive regulation automatically turns off if it is set
that way at commissioning.
Adaptive curve
loop 3
ON – Turn on
OFF – Turn off
Adaptive regulation automatically turns off if it is set
that way at commissioning.
Adaptive curve
loop 4
ON – Turn on
OFF – Turn off
Adaptive regulation automatically turns off if it is set
that way at commissioning.
Pressure of the
source
0.8–1.3 bar
The pressure in the heating system can be a maxi-
mum of 2.5 bars.
Operating instructions
ADAPT, VERSI, ETERA and WPLV systems
17-19-45-6702-07