5 Installation at Site
20 of 60
Multi Eco
5 Installation at Site
5.1 Safety regulations
DANGER
Unsuitable electrical installation
Danger to life!
Make sure the electrical installation meets the VDE 0100 and IEC 60364
installation rules (i.e. sockets with earthing terminals).
Make sure the electric mains is equipped with a residual current device of
maximum 30 mA.
If in doubt, contact a specialist electrical company.
DANGER
Use in an outdoor area
Danger of death from electric shock!
The pump set must be installed at a distance of at least 3 metres from the fluid
reservoir.
Do not expose electrical connections to any moisture.
Any extension cord must match the quality of the supplied cable.
Verify that all sealing elements at the pump's terminal box are properly fitted.
DANGER
Electrical connection work by unqualified personnel
Danger of death from electric shock!
Always have the electrical connections installed by a trained and qualified
electrician.
Observe regulations IEC60364.
DANGER
Using damaged power cables
Danger of death from electric shock!
Never connect any damaged power cables.
Visually inspect the power cable before connecting it.
Replace the power cable if it is damaged.
DANGER
Damaged terminal box
Danger of death from electric shock!
Never operate a pump with a damaged terminal box.
WARNING
Excessive operating pressure
Fluid spurting out and parts flying off as a result of components bursting!
If the pump is to be installed in pressurised piping, fit a pressure reducer
upstream of the pump.