WKT
23
7. Place the distributor casing (10-1) over the drive shaft
and fit it on the top flange of the column pipe main or
on the intermediate shaft bearing and fasten it.
8. Attach hoisting ropes to the distributor casing, raise the
pump, detach and remove the pipe clip, carefully clean
the sealing faces on the barrel and distributor casing,
insert gasket (412.1 or 400.3) and lower the pump until
the distributor casing seats in its correct position on
the barrel flange.
On the construction with gasket, check the parallelism
of the sealing faces between barrel flange and
distributor casing flange.
9. Check the alignment and fasten the distributor casing
on the barrel.
10. Mount the shaft seal and the thrust bearing in
accordance with sections 7.5.2.2 and 7.5.2.3.
11. Adjust the axial position of the pump rotor in
accordance with section 7.5.2.4.
12. Mount the pump end coupling half on drive shaft
(213).
13. Connect the suction line and discharge line, refer to
section 5.7.
14. Mount the driver and check the coupling alignment
(see section 5.6)
15. Fill in oil (see section 6.1.4).
16. Start up the pump in accordance with section 6.2.