Replacement and Adjustment
31
Image Transfer
Image Transfer Belt Unit
1. Remove all the AIO cartridges (→ p.26).
2. Transfer unit (→ p.41)
3. Pull out the waste toner bottle [A].
4. Release the hook [B] under the guide plate.
5. Move the guide plate [C] underneath the fusing unit to the left, and then remove it.