B. STANDARD MODE + WORKSITE EXIT
This mode is intended for use on worksites where the work area is equipped with a set of PTLs to allow vehicles to safely
exit the work area. On an All Red request (see All Red overview below) from the remote control, the PTLs change to yellow
then red, and the worksite PTL change to green. Due to the presence of a minimum of 1 PTL on the worksite, this mode
is only available when 3 or 4 PTLs are paired.
MODE AVAILABLE IF ALL PAIRED PTLs ARE LOCATED AT A MAXIMUM DISTANCE OF 800 M.
POSSIBILITY TO ACTIVATE PLANT CROSSING AUTOMATICALLY VIA THE RADAR EVEN IF ALL PTLs ARE NOT FITTED
WITH IT. MAKE SURE THAT PTLs WITH RADARS ARE POSITIONED ON THE WORKSITE EXIT ROAD(S). THE ID FOR
WORKSITE EXIT PTLs MUST BE B OR D.
PLANT CROSSING CAN BE MANUALLY OR AUTOMATICALY DEACTIVATED.
AUTOMATIC DEACTIVATION TIMING DEPENDS IF PTL ON WORKSITE EXIT IS EQUIPPED WITH REGULATION RADAR OR NOT.
MILLENIUM (NO RADAR) : PLANT CROSSING DURATION = ALL RED TIMING
SMART MILLENIUM (WITH RADAR) : PLANT CROSSING ENDING AFTER 8SEC OF NON DETECTION OR AFTER 30SEC
CYCLES BEGIN AFTER ALL RED ALLOWING THE CENTRAL AREA TO BE FULLY CLEARED.
2 TRAFFIC PTLs
Available choices:
Nbr of site exits: 1 or 2
Varies based on the number of PTLs paired
Available choices:
Worksite light: Light B or B & D
Varies based on the number of PTLs paired
Available choices:
Manual or automatic activation
Automatic: only available on Smart Millenium
OK
NR. PTL
TRAFFIC: 2
PTL
SYNCHRONISED
WORKSITE EXITS:
1 PTL
WORKSITE PTL:
PTL B
PLANT CROSSING
MANUAL ACTIV.
OK
OK
OK
PROGRAMME MODE
FINISHED
OK
3 TRAFFIC PTLs
Available choices:
< 2,000 / 2 to 5,000 / 5 to 8,000 / 8 to 11,000 /
11 to 14,000
Available choices:
20 m to 2000 m
OK
NR. PTL
TRAFFIC: 3
JUNCTION TYPE
CROSSED
NR. VEHIC / DAY
LESS THAN 2,000
SELECT DISTANCE
100m
OK
OK
WORKSITE EXITS:
1 PTL
OK
Available choices:
Crossed ou Rotating
Available choices:
Nbr of site exits: 1 or 2
Varies based on the number of PTLs paired
WORKSITE PTL
PTL B
PLANT CROSSING
MANUAL ACTIV.
OK
OK
PLANT CROSSING
MANUAL DEACT.
OK
Available choices:
Worksite light: Light B or B & D
Varies based on the number of PTLs paired
Available choices:
Manual or Automatic deactivation
Automatic: only available on Smart Millenium
PROGRAMME MODE
FINISHED
OK
Available choices:
Manual or Automatic deactivation
Automatic deactivation timing :
MILLENIUM : plant crossing ending after ALL RED timing
SMART MILLENIUM : plant crossing ending after 8s of non-
detection on or after 30 seconds
Available choices:
Manual or Automatic deactivation
Automatic deactivation timing :
MILLENIUM : plant crossing ending after ALL RED timing
SMART MILLENIUM : plant crossing ending after 8s of non-
detection or after 30 seconds
PLANT CROSSING
MANUAL DEACT.
OK
Available choices:
Synchronised or Crossed