Proline Low-temperature Thermostats
34 Starting up YACE0072 / 21.08.07
7.5 "Master" menu structure
1%21
Actual bath temperature
or actual value of
external temperature
Section 7.6.1
RDr Set setpoint
Section 7.7.1
Os Pump power
Section 7.7.3
Bml Control Int/Ext
Section 7.7.4
LMDkt Settings
Section 7.6.2
LMnet Conf. Modules
Section 7.6.3
RDB Protection system
Section 7.6.9
B/LM Command
Section 7.6.3
B//l Cooling system
Section 7.6.10
@l@ Analog module
Section 8.4
pR Conf. RS232/ 485
Section 8.3
c0a Conf. digit. mod.
Section 8.5
O@pA- Parameters
Section 7.6.4
O0c-- Control par.
Only internal or external
parameters are offered
depending on control
variable
Section 7.6.5 / 7.6.6
RgmY[ Show values
Section 7.6.8
B@K-- Pt100 calibration
Section 7.6.7
B@K 0 Offset int. Pt100
Section 7.8.7
cDE ! Works settgs. int. Pt
Section 7.8.8
B@K D Offset ext. Pt100
Section 0
cDE D Works settgs. ext. Pt
Section 7.8.10
TDp Software version
Section 9.2.2
Rlp^G Serial number Hi Word.
Section 9.2.3
Rlp^K Serial number Lo Word.
Section 9.2.3
RrDKK Control value of tempera.
controller. Section 9.2.4
rGD@c Temp. of housing °C
Section 9.2.4
rGR Temp. of heatsink °C
Section 9.2.4
E@l T Fan voltage in V.
Section 9.2.4
0DEE Mains curr. consumpt. in A
Section 9.2.4
T^RDB Prot. syst. voltage in V.
Section 9.2.4
T13 Act. val. 24V voltage in V.
Section 9.2.4
OT 0 Current consumpt. pump I.
Section 9.2.4
OT O Power consumpt. pump W
Section 9.2.4
OT l Pump speed rpm.
Section 9.2.4
lE 4/ Mains frequency Hz
Section 9.2.4
lT Mains volt. % of rated volt.
Section 9.2.4
KD Bath level [cm]
Section 9.2.4
rD Or Extern temp. Pt100
Section 9.2.4
rD@l@ Ext. temp. analog. interf.
Section 9.2.4
rDRDp Ext.temp. RS232/485
Section 9.2.4
hRDr Curr. controller setpoint.
Section 9.2.4
RDro- Setpoint relat. to act.
val. Section 7.8.4
R Setpoint resolution
Section 7.8.1
Rr@pr Opern. w. mains fail.
Section 7.8.2
rhg Upper temp. limit
Section 7.8.3
Bsp Max. current consumpt.
Section 7.7.5
rhK Lower temp. limit
Section 7.8.3
rXOF- Detect type of unit.
Section 9.2.1
cDE Works setting
Section 7.8.5
@scin Signal settings.
Section 7.8.6
G^@ll Counter operating hours
Master complete
G^OT Counter operating hours
Pump
rc Int. damping time (Td)=
Section 7.13.1
^O Int. proport.range (Xp)
Section 7.13.1
rl Internal reset time (Tn)
Section 7.13.1
rs Int. derivative time (Tv)
Section 7.13.1
rsc Int. contr. par. auto/man.
Section 7.13.1
cDE Works settings
Section 7.13.1
hO External P-controller (Xpf)
Section 7.13.2
Dt Ext. derivative time (Tve)
Section 7.13.2
Dc Ext. damping time (Tde)
Section 7.13.2
Da Ext.propor.range (Prop_E)
Section 7.13.2
Dr/K Ext.correct. var. (K)
Section 7.13.2
D Ext. contr.par. auto/ man.
Section 7.13.2
cDE Works settings
Section 7.13.2
Dl External reset time (Tne)
Section 7.13.2
DO Ext. prop. factor (Kpe)
Section 7.13.2