LAUNCH X-431TOP Users Manual
33
X-431TOP Technical
parameter
Usage Parameter
Working ambient temperature0℃~50
Transporting storage temperature-10℃~70
Working ambient relevant humidity 20%
90%(40)
Transporting storage relevant humidity20%
90%(40)
Pressure: 86kpa106kpa
Oscilloscope Technical
Parameter
X-431TOP Technic parameter
Oscillograph technic parameter
Collection:
1.time resolution range: 2.5μs,5.0μs,10.0μ
s,25.0μs,50.0μs,100μs,250μs,500μ
s,1.0ms,2.5ms,5.0ms,10.0ms,25.0ms,50.0ms,10
0ms,250ms,500ms,1.0s,2.5s,5.0s,10.0s.
2. signal mode: DC/ AC
Channels:
1.Coupling mode: DC,AC.
2.Measuring range: 5.0mv/div10.0mv/div
20.0mv/div50.0mv/div100.0mv/div
200.0mv/div500.0mv/div1.0v/div2.0v/div
5.0v/div10.0v/div20.0v/div.
Trigger:
1.Trigger channel: one of the CH1,CH2, CH3 and
CH4.
2.Default trigger channel: CH1.
3.Default trigger level: 0mv.
4.Default level range: 6X(the measuring range of
trigger channel).
Measuring :
1. Voltage Differential between cursor: (the
measuring range of the channel)/ 50.
2. Time differential between cursor: (the time
resolution range of any channels)/50.
Precision:
1. Time resolution: 2.5μs;
2. Voltage resolution: 5mv;
3. Time precision: ±5%.
4. Voltage precision: ±5%.
Engine Analysis Parameter
1. Engine speed: measuring range
500-7200r/min.
2. Real VCY_ICCANG (Platinum Close Angle (%):
measuring range 0-90°( cam bearer).
Precision:
1.Engine speed: indication error is less than 1%.
2.Real VCY_ICCANG (Platinum Close Angle
(%):indication error is less than
±1( cam bearer).
Sensor Test Technical
Parameter
Sensor test
Voltage test:
1.Measuring range: DC -400+400V
2.Input impedance: 10M.
Voltage test:
Measuring range: 01 M0hm
Frequency test:
1.Measuring range: 115kHz
2..Input impedance: 300kOhm
3.Input range: 112V
Precision:
Check precision: ±1%
Sensor simulate function:
DC voltage signal:
1.Output range: -12V+12V
2.The maximal output current: 40mA
Squarl-wave signal:
1. Impulse frequency: 0.115kHz
2. Range: -12V+12V
3. Duty ratio: 10%90%
Sensor standard signal:
1. Frequency range: 0.1100Hz
2. Range: -12V+12V
Hand-draw waveform Signal:
1. Frequency range: 0.1100Hz
2. Range: -12V+12V
Simulation precision rate: