19PIR II User manual - NE41 19003-00 v1.2
13.5 DIP5 - IR detection sensitivity
Set to ON for low sensitivity and OFF for high sensi-
tivity.
DIP5 is ignored if DIP3 is set to ON and sensitivity is
automatically set to High.
13.6 DIP6 - Operation LED aer alarm
Set to ON to have the PIR II indicating with the Opera-
tion LED (D2) when an alarm is sent.
The operation LED will always indicate start-up
regardless of this DIP setting.
13.7 DIP7 - Detection LED aer movement
Set to ON to have the PIR II indicating with the Detec-
tion LED (D1) when a movement is detected.
13.8 DIP8 - Disable OFF button (S5)/Alarm delay
The function of DIP8 depends on whether DIP3 is set
to ON or OFF.