Assembly of
column~
base
Safety ring
~
column
Cross-member
~
column
Horizontal arm
~
cross member
Drive housing
~
horizontal arm
Swinging-arm stand
ESD
The swinging-arm sta
nd
ESO
is of conducting material [s
urf<Jc
e
r
es
istance
<10
11
Ohm
/squared, discharge time <2 secon
ds
from
1,
000
V
to
100
V)
. Two sockets for connecti
ng
0 4
mm
ground
cables are provided
on
the base.
~
Inse
rt
4 Alien screws into the
base
fr
om
beneath
and
secure them to
the
end
of
the column.
,&..
The safety ring secures the instrument and must
always
•
~:!;:;:~;~~~;~:·
~.
"""~ornbO<
tl
~
Retighten the clamping screw.
~
~
Lower the cross-member onto the
safety ring.
~
Retighten the clamping
screw
.
~
Slide the horizontal arm into the
cross-member with the connecting
piece towards you.
~
Retighten the clamping
screw
.
~
~
• The drive housing I microscope carrier can
be
fitted to
the horizontal arm in either of two positions (see page
34).
• The circular port in the microscope
carrier accepts
an
illuminator.
~
Insert the
pe
g of the
in
clinable focusing
drive into the connecting piece.
~
Retighten the clamping screw.
Optics
carrier-+
~
Fitthe optics carrier in the
Q
28
microscope carrier microscope carrier.
~Turn
the optics carrier sideways
in
the microscope carrier
as
requir
ed
.
~
Retighten the clamping screw.
Le
ica M Stereomicros
cop
es
- Assemblv
l ' '
Focusing
Tilting
Altering the
working
distance
Sideways movement
Altering the overhang
The
focusing knob s are located
on
the inclinable drive housing.
Is the focus movement too loose or too tight? Does the outfit
tend to slide downwards?
You
can adjustthe movement in
accordance with the
weight
of the outfit
and
with your own
personal requirements:
~
Hold the drive knobs firmly with both
hands
and
turn them
in
opposite direc-
tions until you obtain the required degree
of resistance during focusing.
Possible adjustments
~
Release the clamping screw.
~
Tilt the instrument.
~
Retighten the clamping
screw
.
~
Release the clamping
screw
.
~
Raise or lower the cross-member
as
re-
quired together with the horizontal arm.
~
Retighten the clamping
screw
.
Reposition the safety ring (see page
28).
~
Release the clamping
screw
.
~
Move the instrument sideways
on
the crass-member.
~
Retighten the clamping
screw
.
~
Release the clamping screw.
~
Displace the horizontal arm .
~
Retighten the clamping
screw
.
Le
i
ca
M Stereomicros
co
pes - Ass
emb
ly
29