104
WATER AND PLUMBING SYSTEM UNITY MOTORHOME
WATER PUMP INITIAL STARTUP
1 Make sure all drain valves are closed.
2 Turn off the water pump switch
4
3 Fill the water tank.
4 Open the hot and cold faucets
5 Turn on the water pump switch
4
6 Close each faucet (hot and cold) as soon as
water ows steadily through the faucet.
7 Verify that the water pump stops after closing all
faucets
8 The water pump is now ready for automatic
operation
4
WATER PUMP TROUBLESHOOTING
IF THE PUMP WILL NOT PRIME
1 Make sure there is water in the tank.
2 Make sure the chassis battery is not discharged.
3 Make sure there are no kinks or obstructions in
the inlet hose
4 Make sure all inlet ttings and connections are
air tight
5 Make sure water selector valve
5
in the exterior
utility center is set to "NORMAL POSITION"
6
as shown
5
6
6 Check for clogged screens.
WATER PUMP
The water pump
1
is designed to supply on-demand
water from the fresh water tank to the various water
and plumbing systems in your motorhome When a
faucet is opened, the pump comes on automatically
and pressurizes the various water lines.
1
2
Periodically check the screen
3
on the intake
side of the water pump
1
. Clean or replace
the screen at least annually to ensure proper
water pressure. Unscrew the lter bowl
2
to
access the screen remove the screen, and
clean with fresh water. Replace in reverse
order, ensuring the lter bowl is securely
tightened. Refer to the water pump owners
manual located in the Motorhome Information
Kit for further information.