86
ELECTRICAL SYSTEM OPERATION UNITY MOTORHOME
STARTING THE AUXILIARY LP GAS
GENERATOR
1 Depress and hold the top of either of the two
generator start buttons until the generator starts
running then release the button
NOTE: The buttons can be found in either of two
locations One is located on the generator
3
(location may vary based on oor plan; check
"Unity Floor Plans" page 8). The second button
is located in the electrical utility panel (cabinet
above the entrance door).
2 Allow the generator engine to settle and run
smoothly before operating any electrical
appliances
3 Become familiar with the output capacity and
capability of your generator
4 Be careful not to overload the generator. Refer
to the generator manual in the Motorhome
Information Kit for further details
3
4
6
7
STOPPING THE AUXILIARY LP GAS
GENERATOR
Prior to stopping the generator, turn off all large
appliances and let the generator run for two minutes
to cool down
To stop the generator, depress and hold the bottom
of the generator stop button
4
until the generator
engine has completely stopped
OPERATING THE AUXILIARY LP
GAS GENERATOR
Turn on the LP Gas valve by depressing the top of
the LP Gas shut off switch
1
located in the utility
center in the driver’s side exterior compartment.
1
The generator starter draws power from the
coach batteries, so the chassis ignition switch
does not have to be on for the generator to
operate.
NOTICE
The LP Gas generator control panel
2
is located in
the overhead cabinet above the coach entrance door.
2
4
3
5

Table of Contents