EasyManua.ls Logo

LELY Discovery 120 Collector - Page 79

LELY Discovery 120 Collector
90 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.4008.8520.0 -
Troubleshooting 9-5
Table 9 Troubleshooting table machine (cont'd.)
Symptom
Possible cause Action
The machine does not stop at the
charging station.
The charging strips or electrodes
do not make contact.
Clean the electrodes and
charging strips.
The power supply of the
charging station is not working.
Make sure the charging station is
connected to the power supply
(see table 10 on page 9-5).
The machine does not stop at a
bump point.
The route is not programmed
correctly.
Contact your local Lely service
provider to have the route
reprogrammed.
The map of the barn is not
programmed correctly.
Contact your local Lely service
provider to have the map
reprogrammed.
Table 10. Troubleshooting table charging station
Symptom
Possible cause
Action
All the LEDs on the charging
station are off.
The power supply is broken /
disconnected.
Check if the power plug is in
the outlet.
Check if the power supply to
the power outlet is OK.
Green and Yellow LED
together blink 2 times, followed
by a few seconds rest
Battery loader defect. Contact your local Lely service
provider.
Green and Yellow LED
together blink 4 times, followed
by a few seconds rest
Temperature lower than - 15
degrees C (5 degrees F).
Warm the barn and try again.
Battery loader defect. Contact your local Lely service
provider.
Green and Yellow LED together
blink 5 times, followed by a few
seconds rest.
Internal temperature is higher
than 85 degrees C (185 degrees
F).
Remove plug from the mains.
Connect plug and retry after one
hour.
Green and Yellow LED together
blink 7 times, followed by a few
seconds rest.
Current too high (>20 A). Remove short-circuit, else:
Call your local Lely service
provider.
in n o vato rs in ag ric u ltu re