Table31.SubmenusundertheMassStorageControllerConguration
ItemOptionDescription
SATACongurationDisabled[Enabled]EnableordisabletheintegratedSATA
controller.
CongureSATAas[IDE]RAID
Toselecttheharddiskdrivemode.
IfthisoptionissettoIDE,allthe
SATAconnectorswillbecongured
asstand-aloneSATAconnectors.
Notes:
1.Thesettingsin[]arethedefaultsettingsintheSetupUtilityprogram.
2.TheSATACongurationitemmightnotapplybecauseyourservercamewithanintegratedSAScontroller.
Table32.SubmenusundertheSuperIOConguration
ItemOptionDescription
SerialPort1AddressDisabled[3F8/IRQ4]3E8/IRQ42E8/IRQ3SelecttheI/Obaseaddressand
interruptforserialport1.
SerialPort2AddressDisabled[2F8/IRQ3]3E8/IRQ42E8/IRQ3SelecttheI/Obaseaddressand
interruptforserialport2.
Note:Thesettingsin[]arethedefaultsettingsintheSetupUtilityprogram.
Table33.SubmenusundertheUSBConguration
ItemOptionDescription
LegacyUSBSupportDisabled[Enabled]Auto
Enableordisablethesupporton
legacyUSBdevices.
USB2.0ControllerModeFullSpeed[HiSpeed]SelecttheUSBspeed.
HotplugUSBFDDSupportDisabledEnabled[Auto]
Enableordisablethesupportonthe
hot-swapUSBdiskettedrive.
Note:Thesettingsin[]arethedefaultsettingsintheSetupUtilityprogram.
ForexternalUSBdevices,theUSBMassStorageDeviceCongurationsubmenuisasbelow:
EmulationType
[Auto]FloppyForcedFDDHard
DiskCDROM
SelectthetypeoftheUSBdevice.
Table34.SubmenusundertheHardwareHealthConguration
ItemOptionDescription
ItemsandoptionswithBMCconguration:
AutoFanControlDisabled[Enabled]
IfthisoptionissettoDisabled,the
fanrunsatthefullspeed;ifthisoption
issettoEnabled,thefanspeedis
controlledbythesystemtemperature.
PWMMinimalDutyCycle[60%DutyCycle]45%DutyCycle30%
DutyCycle
SelectthePWMMinimalDutyCycle
forthefan:60%-100%,45%-100%,
or30%-100%.
SensorDataRegisterMonitoringReadOnly
Thesensordatainthisoptionisfor
readonly.Thedetecteddataincludes
thetemperature,voltageandfan
speed.
ItemsandoptionswithoutBMCconguration:
Chapter8.Conguringtheserver113